ABOUT ME

-

Today
-
Yesterday
-
Total
-
  • Siemens Opc Scout V10 Download Google
    카테고리 없음 2020. 2. 20. 07:50

    On the path to digitalization – thanks to open, platform-neutral communication with OPC UAWhen it comes to networking and standardization or cybersecurity – the requirements for industrial networks are increasing at an ever-faster pace. In this problematic area, the open, Ethernet-based OPC UA (Open Platform Communications – Unified Architecture) communication standard is experiencing rapid growth. With its integrated security mechanisms, vendor- and platform-independent OPC UA provides the best foundation conditions for digitalization.

    Siemens Opc Scout V10 Download Google Drive

    Siemens relies on OPC UA for vertical connection and for communication between machines (M2M) – and it’s combining the advantages of OPC UA with those of PROFINET in Industrial Ethernet networks. To handle the requirements of tomorrow’s industry, industrial networks will need to be able to meet ever-increasing demands.

    Companies will need convergent, end-to-end, secured networks that are flexibly scalable, dynamically adaptable, and able to accommodate large numbers of users – naturally, with the fastest possible response times.OPC UA is an important component: The open, platform-neutral communication standard enables seamless communication with third-party applications and can be flexibly scaled to meet specific requirements. With its semantic capabilities, OPC UA supports more than just data transmission: It also contains a unique information model. Proven security mechanisms like authentication, authorization, and encryption guarantee a secure connection.

    Siemens Opc Scout V10 Download Google

    In addition, PROFIsafe mechanisms are being prepared for OPC UA to permit standardized, safety-related communication between machines. OPC UA can also be integrated into existing Industrial Ethernet networks and can run on the existing PROFINET infrastructure without compromising performance.That’s why Siemens relies on OPC UA as the number-one open interface from the control level to higher-level SCADA, MES, and ERP systems all the way to the cloud.

    OPC UA with client/server communication is used extensively in automation. With this proven, one-to-one communication mechanism, each OPC UA client obtains access to the data on the OPC UA server via point-to-point communication. The OPC UA client sends a request to the OPC UA server, from which it receives a response. This form of communication enables a reliable, secure, encrypted data exchange with reduced bandwidth and no loss of data, even if the environment and network quality are sub-optimal and are experiencing disturbances. Client/server communication is always based on TCP/IP. In the OPC UA with PubSub (publish/subscribe) model, a one-to-many or many-to-one communication mechanism is used: A publisher makes data available that can be received by any number of subscribers in the network.

    OPC UA PubSub communication can be transmitted via UDP or directly on layer 2. Depending on the technology used, this can result in short cycle times. In conjunction with Time-Sensitive Networking (TSN), OPC UA PubSub therefore enables real-time communication at the control level and meets the demands of time-critical applications. Guaranteed, scalable bandwidths, optimized Quality of Service (QoS) mechanisms, real-time capability, and very low transmission latency in communication networks: Siemens relies on Time-Sensitive Networking (TSN) to get the most out of automation networks while meeting constantly growing requirements.

    Siemens Opc Scout V10 Download Google Browser

    As a result, communication from machine to machine and from machine all the way up to the operator level can achieve new heights in terms of speed and reliability. TSN is defined within the framework of IEEE 802.1 and combines a series of individual standards that affect only the data-link communication layer (layer 2). Standardized interface and widespread availability. Secured communication directly in the protocol with no additional hardware.

    Direct connection and communication across all automation levels. Easy and unambiguous interpretation of data. Simple Ethernet-based networking, uses existing Industrial Ethernet infrastructure. Internationally standardized interfaces for simple machine integration (companion specifications). High performance thanks to fast communication.

    When TSN hardware and OPC UA PubSub are used, OPC UA data can be transmitted deterministically, independent of the network load. Open Platform Communications – Unified Architecture (OPC UA) was developed by the OPC Foundation, which was created in 1996 with Siemens as a founding member. The OPC Foundation is an international nonprofit organization with over 450 members from all sectors of industry. It works closely with users and vendors to develop the open, vendor-independent standard – and it does so successfully, according to this statement by Holger Junker of the German Federal Office for Information Security (BSI): “The only communication technology in the factory with implicit security features and the potential to meet the challenges posed by Industrie 4.0 that I am aware of today is OPC UA.”.